Application Area

- Channel of the partition wall is fastened to the floor and to the ceiling with an anchor at every 60 to 80 cm. It is recommended to apply rubber tapes (Westeltape) to the channel’s surface which faces
- Studs of the partition wall are mounted inside the channels to create the frame of the partition wall. Studs in which the insulation material is to be filled are installed in channels back to back at
- After completing the load-bearing construction of the partition wall, rubber tapes (westeltape) are also recommended to apply stud’s surface to avoid sound bridges. Then, gypsum boards are installed o
- “Westel Partition Wall Board” of 60 cm width are installed between studs and gypsum boards are installed on the other surface
- Self-adhesive plaster mesh is cladded on the joint sections of the gypsum boards. After applying plaster, surfaces can be painted as desired.

Technical Specifications
| Properties | Unit | Description | Tolerans | Standard | |||||||
| Width | mm | 600 | +/-1,5% | TS EN 822 | |||||||
| Length | mm | 1200 | +/-2% | TS EN 822 | |||||||
| Thickness | mm | 40* | 50 | 60 | 80 | 100 | T3(**) | TS EN 823 | |||
| Reaction to Fire | – | A1 | – | EN 13501-1 | |||||||
| Squareness | mm/m | max.5 | – | TS EN 824 | |||||||
| Flatness | mm | max.6 | – | TS EN 825 | |||||||
| Dimensional Stability | % | max.1 | – | TS EN 1604 | |||||||
| Maximum Service Temperature | °C | 250 | – | – | |||||||
| Specific Heat (***) | kJ/(kg.K) | 0.84 | – | EN 12524 | |||||||
| Water Vapor Diffusion Resistance Coefficient (*** | – | 1 | – | TS EN 12086 | |||||||
| Dynamic Elasticity (***) | kN/m2 | 0.8 | – | DIN 52214 | |||||||
| Packaging Material | – | PE Film | – | – | |||||||
* Produce as a plus.
** T3: -3% or -3 mm; +10% or 10 mm. The biggest value is chosen at minus tolerance, the smallest value is chosen at plus tolerance.
*** Literature value.